iPAC-120CC Ceiling Cassette System 12Kw – 42000 BTU

//iPAC-120CC Ceiling Cassette System 12Kw – 42000 BTU

iPAC-120CC Ceiling Cassette System 12Kw – 42000 BTU

iPAC-120CC – 42000 BTU System

Recommended room size of 50-100 m²

Our EASYfit split air conditioning units are perfect for both residential and commercial use. The KFR-120QIW/X1C is a highly energy efficient, easy to install, multipurpose super inverter ceiling cassette unit and can be used all year round. It will keep your home or office cool and fresh during the summer months and toasty and warm throughout the winter.

  • Adjustable fan speeds for rapid cooling or minimum noise
  • Oscillating air vanes for maximum dissipation of cold air
  • Timer feature to turn the unit on and off automatically
  • Air filters to remove odours and particles
  • Anti-mould coating for hygienic operation
  • Digital display
  • Heat pump model provides heating as well as cooling

 Warranty 

1. Installed by F-Gas registered installer.

2. Systems must be serviced by F-Gas registered installer.

3. Warranty + Services must be registered with Air Conditioning Centre.

Highly Efficient – Simple to install

Our split system air conditioning units consist of an indoor and outdoor unit, connected via copper piping. The outdoor unit contains the condenser and removes heat and condensation from the room, dissipating it outside. All our AC units are heat pumps and are able to both heat and cool. The outdoor unit of this system can also be installed using our optional Bracket Kit if required.

   File:PDF file icon.svg     View Full Product Datasheet

View our Stockists

All ACC products are guaranteed for 12 months (unless otherwise stated) from the date of original purchase. For more information about our Warranty click here.

Description

INDOOR UNIT

Indoor unit Dimension (W  x Dx H)(body) mm 830x830x287
Packing   (W  x Dx H)(body) mm 910x910x330
Dimension (W  x Dx H)(panel) mm 950x950x55
Packing  (W  x Dx H)(panel) mm 1035x1035x90
Net/Gross weight(body) kg 29.3/33.5
Net/Gross weight kg 6/9

OUTDOOR UNIT

Outdoor unit Dimension(W*D*H) mm 946x410x810
Packing  (W*D*H) mm 1090x500x885
Net/Gross weight Kg 71.0/75.0

INDOOR UNIT 

Indoor  Model iPAC-120CC
Indoor Code 22022511003338
Average Pdesignc kW 12.1
SEER W/W 6.1
Energy Efficiency Class A++
Seasonal space cooling energy efficiency(ηs,c) %
Pdesignh kW 9.5
SCOP W/W 4.0
Energy Efficiency Class A+
Seasonal space heating energy efficiency(ηs,h) %
Tbiv -7
Warmer Pdesignh kW 9.8
SCOP W/W 5.1
Energy Efficiency Class A+++
Tbiv 2
Tol -15
Power supply    (Indoor ) V,Hz,Ph 220-240V,1Ph,50Hz
Power supply    (Outdoor ) V,Hz,Ph 220-240V,1Ph,50Hz
Cooling Capacity Btu/h 41000(10000~42000)
Capacity kW 12.02(2.93~12.31)
Input W 4200(680~4350)
Current A 18.8(3.1~19.1)
Heating Capacity Btu/h 46000(11500~48000)
Capacity kW 13.48(3.37~14.07)
Input W 3700(750~4250)
Current A 16.3(3.4~19)
Indoor fan motor Model ZKFN-125-8-1
OldModel ZKFN-125-8-1
Qty 1
Input w 157
Capacitor uF /
Speed(hi/mi/lo) r/min 712/648/584
Indoor coil a.Number of rows 3.0
b.Tube pitch(a)x row pitch(b) mm 21×13.37
c.Fin spacing mm 1.3
d.Fin type (code) Hydrophilic aluminum
e.Tube outside dia.and type mm Φ7,Inner groove tube
f.Coil length x height x width mm 980x252x40.11+980x252x40.11
g.Number of circuits 10
Indoor air flow (Hi/Mi/Lo) m3/h 1900/1750/1600
Indoor sound pressure level (Hi) dB(A) 52.5/50/47.5/40
Indoor sound power level (Hi) dB(A) 65
Outdoor sound pressure level (Hi) dB(A) 63
Outdoor sound power level (Hi) dB(A) 71
Indoor unit Dimension (W  x Dx H)(body) mm 830x830x287
Packing   (W  x Dx H)(body) mm 910x910x330
Dimension (W  x Dx H)(panel) mm 950x950x55
Packing  (W  x Dx H)(panel) mm 1035x1035x90
Net/Gross weight(body) kg 29.3/33.5
Net/Gross weight kg 6/9
Design pressure MPa 4.3/1.7
Drainage water pipe dia. mm ODΦ25mm
Refrigerant piping Liquid side/ Gas side mm 9.52mm(3/8in)/15.9mm(5/8in)
Controller Standard Remote Control
Operation temperature 16~30
Room temperature Cooling 16~32
Heating 0-30
Qty’per 20’ /40’ /40’HQ Indoor unit 84/182/208

OUTDOOR UNIT 

Model iPAC-120CC
Code 22022516001724
Power supply V,Hz,Ph 220-240V,1Ph,50Hz
Max. input consumption W 5000
Max. current A 22.5
Compressor Model KTF310D43UMT
Type ROTARY
Brand GMCC
Capacity W 10010
Input W 2765
Rated current(RLA) A 5.38
Refrigerant oil/oil charge ml VG74/1000
Outdoor fan motor Model ZKFN-120-8-2
Old Model WZDK120-38G-W
Qty 1
Input W 150
Capacitor uF /
Speed r/min 950/750
Outdoor coil a.Number of rows 2.6
b.Tube pitch(a)x row pitch(b) mm 25.4×22
c.Fin spacing mm 1.5
d.Fin type (code) Hydrophilic aluminum
e.Tube outside dia.and type mm Φ9.52,Inner groove tube
f.Coil length x height x width mm 995x762x22+960x762x22+580x762x22
g.Number of circuits 6
Outdoor air flow 4000
Throttle type EXV+Capillary
Outdoor unit Dimension(W*D*H) mm 946x410x810
Packing  (W*D*H) mm 1090x500x885
Net/Gross weight Kg 71.0/75.0
Refrigerant type Type R32
GWP 675
Kg 2.8
Design pressure MPa 4.3/1.7
Refrigerant piping Liquid side/ Gas side mm(inch) 9.52mm(3/8in)/15.9mm(5/8in)
Max. refrigerant pipe length m 75
Max. difference in level m 30
Ambient temperature Cooling -15~50
Heating -20~24

Reviews

There are no reviews yet.

Be the first to review “iPAC-120CC Ceiling Cassette System 12Kw – 42000 BTU”

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.